The Carbo-M is a dual-channel measuring and control system for C level calculation and C level and temperature control in the furnace atmosphere of heattreatment plants.
By means of switch settings on the rear panel of the instrument, Carbo-M can be easily adapted to match existing facilities. Alterations in the data acquisition scheme, for example, change of gas analyzers to oxygen probes, can be effected without difficulty.
A currently available analytical method for determining the carbon content in furnace atmospheres is the indirect measurement of the oxygen content in the furnace with zirconiumoxide probes. Carbo-M provides special support for these methods. Data sheets on probes and other equipment are available on request.

주요 특징
  • 메뉴 안내 운용 방식
  • CP 및 온도 정밀 제어
  • 수트(그을음) 발생 제한 감시
  • 다양한 센서와 결합 가능. O2, O2 + Co2, Co 및 온도센서 K 또는 S 타입
  • O2 센서 모니터 (Ri, EMF 및 퍼징)
  • 동시에 2개 센서 측정 가능
  • 스페어 센서로 자동 변환
  • CP 및 온도에 대하여 99개 세트 포인트 프로그램 저장
  • 아날로그 출력 가능 (기록 및 출력용)
  • CP 교정 (Foil Tester로 정밀 측정하여 교정)
  • 포일 키패드
기술 사양
구  조 판넬 설치용 금속 하우징
크  기 144 x 144 x 300mm (길이 x 폭 x 높이)
전원 공급 230 VAC ± 10%. 50/60 Hz
전력 소모 약 15 VA
입력 신호 스위치 세팅에 의하여 선택
아날로그
O2 센서 셀전압 또는 증폭기
O2 센서와 Co 분석기
CO2 분석기
CO2 분석기와 Co 분석기
O2 센서와 L – probe
O2 센서, L – probe와 Co 분석기
온도센서 Type K or S (또는 혼합)
터미널 온도센서 PT 100
외부 세트값 직렬 인터페이스
기술자료
Construction
Metal housing for mounting in control panels, in conformance with DIN 40050 Type of protection IP 54 (front), as specified in DIN 50050
Dimensions
144 x 144 x 300 mm (l x w x h)
Auxiliary voltage
230 Vac ± 10 % 50/60 Hz
Power consumption
About 15 VA
Input signals (selected by means of switchsetting)
Analog (in following combinations)
O2 measuring probe, cell voltage directly or through amplifier O2 measuring probe and CO analyzer CO2 analyzer CO2 analyzer and CO analyzer O2 probe and L-probe O2 probe, L-probe and CO analyzer L-probe and CO analyzer L-probe and CO2 analyzer L-probe, CO2 analyzer and CO analyzer L-probe and L-probe O2 probe and O2 probe CO2 analyzer and O2 probe
Attention
If you use L-probe and O2 -probe you can´t connect an additional Reference junction.
Reference junction, type K or S (also mixed) Terminal temperature (Pt 100)
External set value: serial interface
Digital
IN 0: program release with set point program in progress: otherwise, controller locked IN 1: program continuation in succession IN 2: input disable
Accessories
Auxiliary unit REL.., PRL… Adapter for terminal strips